1%-5%RH Electronic Dry Cabinet TDU1436F-6

<5% Electronic Dry Cabinet  

1436L Buy dry storage cabinet for sale, low humidity storage cabinet

Model: TDU1436F-6

Color: Black, ESD safe

Humidity Range: <5%RH automatic

Interior Dimension: W1198×D682×H1723mm

Exterior Dimension: W1200×D710×H1910mm

Packing Dimension: W1300 ×D800×H2230mm

Shelves: 5pcs

Voltage: 110V/220V/230V/240V 50/60HZ

Remark: White color is not ESD safe

Share to:

Description

Desiccant dry box is ready-to-use moisture-proof solutions for electronics assemblers, PCB manufacturers, and component distributors and manufacturers, the dry box can regulate and maintain specific humidity levels, providing optimal storage conditions for sensitive items. All of our dry box and cabinets comply with IPC specifications.

Humidity-controlled drying and storage for electronic components

In surface mount technology (SMT) applications, the desiccant dry box is critical for storing sensitive components such as solder paste, circuit boards, and other electronic components that may be affected by humidity.

Application - TDU98BFD

High ambient humidity can cause electronic components to absorb moisture, especially during reflow soldering. This phenomenon is known as “popcorning,” in which moisture trapped in a component rapidly expands when heated, causing internal pressure and potential damage.

Using desiccant dry box can minimize the risk by keeping components in an ultra low-humidity environment, thereby reducing moisture absorption, NetDry cabinets follow industry regulated IPC standard.

 auto Dry Cabinet Tdu1436f 4 7

Features

  • Electronically controlled dehumidifying system
  • Minimize moisture and protect your storage items from dust and dirt
  • Module design: Each module can be replaced individually
  • With the memory function, no need to reset after a power outage
  • User-Friendly Interface

Video

Specification

Model

Capacity

Interior Dimension

(W×D×H,mm)

Exterior Dimension

(W×D×H,mm)

Gross Weight (KG)

Average Power (Watts)

Max. Loading

/Shelf(KG)

TDU98

98L

446×372×598

448×400×688

31

6

50

TDU98F

98L

446×372×598

448×400×688

31

6

50

TDU160

160L

446×422×848

448×450×1010

43

10

50

TDU160F

160L

446×422×848

448×450×1010

43

10

50

TDU240

240L

596×372×1148

598×400×1310

57

10

50

TDU240F

240L

596×372×1148

598×400×1310

57

10

50

TDU320

320L

898×422×848

900×*450×1010

70

40

80

TDU320F

320L

898×422×848

900×450×1010

70

40

80

TDU435

435L

898×572×848

900×600×1010

82

40

80

TDU435F

435L

898×572×848

900×600×1010

82

40

80

TDU540

540L

596×682×1298

598×710×1465

95

60

80

TDU540F

540L

596×682×1298

598×710×1465

95

60

80

TDU718

718L

596×682×1723

598×710×1910

105

60

80

TDU718F

718L

596×682×1723

598×710×1910

105

60

80

TDU870

870L

898×572×1698

900×600×1890

130

80

100

TDU870F

870L

898×572×1698

900×600×1890

130

80

100

TDU1436-4

1436L

1198×682×1723

1200×710×1910

189

120

100

TDU1436F-4

1436L

1198×682×1723

1200×710×1910

189

120

100

TDU1436-6

1436L

1198×682×1723

1200×710×1910

189

120

100

TDU1436F-6

1436L

1198×682×1723

1200×710×1910

189

120

100

Option:

1) Over-humidity alarm buzzer

2) Door-opening alarm buzzer

3) Three-color alarm flashing light

4) Data logger with USB interface

Working Principle

The desiccant dry box adopts active dehumidifying system to maintain low humidity levels, automatically adjusting humidity. This allows sensitive items to be stored safely and protected from moisture-related issues and electrostatic discharge (ESD).

The dehumidifying system is controlled by a microcomputer. When the internal humidity is high, it starts to absorb moisture; when the humidity reaches the set value, it stops absorbing water and discharges water outside. This process is automatic control.

Dry Box For Electronic Components 9

This chart shows, in the ambient 25 degree C, humidity 50%RH, open door 30 seconds and then close, the humidity can recover to the set point within 30 minutes.

Drying And Storage Cabinet 9

Applications

  • Electronics: Protect printed circuit boards, sensors, and connectors from moisture-related damage.
  • Optics and Photography: Prevent mold and fungus in lenses, cameras, and precision instruments.
  • Laboratory Equipment: Store sensitive reagents, medical supplies, and instruments.
  • Industrial Storage: Protect parts, tools, and machinery components.

By controlling humidity, these desiccant dry box and cabinets help extend the service life and maintain the quality of sensitive items in various industry.

Advantages

  • Prevent Static-Related Damage
  • Precise Humidity Control
  • Improve Shelf Life for Sensitive Items
  • No Consumables, no Replacement
  • Ease of Use and Maintenance
Desiccant Dry Box Tdu1436f 6 7

Humidity storage reference

Relative Humidity

Suggested storage items

55%~45%RH

Tapes, CD, lenses, microscope,photograph, oil paintings, stamps, coins, antiques, leather goods, negative, drawings, album, slides, industrial design, etc

45%~35%RH

Optical lenses, precision instruments, camera, lenses, measuring tools,capacitors, batteries, EI, light sources, crystal, PCB, detector, charger, microscopes, endoscopes, electronic appliance, magnetic tape, chemical, tea, coffee, seeds, cigarette, etc.

35%~20%RH

Samples,filters, precision dies,measurement instruments, pollen, all electronic components, PCB, wafer, metallic powders, semiconductors, medical supplies etc.

10%~20%RH

Electronic components, PCB, crystal, chemical, LED and other complicated electronic components, etc.

10%-1%RH

IC, BGA, copper, silver, and materials very sensitive to humidity,etc

Q&A

Why is the dry cabinet necessary for SMT industry?

. Preventing Moisture-Induced Damage

. Extending Shelf Life of Components

. Compliance with Industry IPC/JEDEC J-STD-033 Standards

. Minimizing Manufacturing Defects

Yes, the minimum adjustable height is 25MM.

Relative humidity is a very sensitive coefficient and is easily affected by the external environment. Therefore, the recovery time depends on many factors, such as the door opening time, surrounding environment, and storage items. Under normal circumstances, when the ambient temperature is 25 deg C and the humidity is < 60%RH, if the door opening time is within 15 seconds, the humidity can reach below 5%RH within 15-30 minutes.

Some electronic components, such as PCB, BGA, IC, chips, etc., require low humidity storage environment. Desiccant storage cabinets can control humidity and protect them from moisture immersion, making drying cabinets the optimal choice for storing electronic components. Electronic devices in the process of operation, semi-finished products in packaging for the next process, unused ICs, BGAs, PCBs after unpacking, devices waiting in the oven, devices waiting for temperature to be returned after baking, and unpackaged finished products can be damaged by moisture.

The humidity sensor accuracy is +/-2%RH, the long-term drift is <0.25%RH/yr, and we have calibrated every unit before ex-factory. We suggest that no need calibration is required for the first 2 years, if it is indeed required, we recommend using the ROTRONIC, Swiss-made hygrometer HP21, HP22 or HP23.